If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
100WQuadOutputwithPFCFunction 1 0 0 W Q u a d O u t put with PFC Function Features: Q P --1 0 0 sseer ri eess qp 100 i .. SPECIFICATION MODEL OUTPUTNUMBER DCVOLTAGE RATEDCURRENT CURRENTRANGE RATEDPOWER (max.) OUTPUT VOLTAGE ADJ.RANGE VOLTAGETOLERANCE Note.3 LINEREGULATION LOADREGULATION SETUP,RISETIME HOLDTIME (Typ.) VOLTAGERANGE FREQUENCY RANGE POWERFACTOR (Typ.) INPUT EFFICIENCY (Typ.) ACCURRENT (Typ.) INRUSHCURRENT (Typ.) LEAKAGECURRENT OVERLOAD PROTECTION OVERVOLTAGE OVERTEMPERATURE(OPTION) WORKINGTEMP. WORKINGHUMIDITY ENVIRONMENT STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTANDVOLTAGE QP-100-3A CH1 5V 8A 2~10A 99.4W CH1:4.75~5.5VCH2:3.14~3.63V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% 6.0% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 3.3V 8A 0~10A CH3 12V 2.5A 0.3~3A CH4 -5V 0.6A 0~1A QP-100-3B CH1 5V 8A 2~10A 100W CH1:4.75~5.5VCH2:3.14~3.63V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% 6.0% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 3.3V 8A 0~10A CH3 12V 2.2A 0.3~3A CH4 -12V 0.6A 0~1A QP-100-3C CH1 5V 8A 2~10A 100.9W CH1:4.75~5.5VCH2:3.14~3.63V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% +8,-6% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 3.3V 8A 0~10A CH3 15V 1.7A 0.3~2A CH4 -15V 0.6A 0~1A RIPPLE&NOISE(max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 800ms,50ms/230VAC 800ms,50ms/115VACatfullload 24ms/230VAC24ms/115VACatfullload Note.5 90~264VAC127~370VDC 47~63Hz PF>0.95/230VACPF>0.98/115VACatfullload 74% 1.5A/115VAC0.75A/230VAC COLDSTART 40A/230V <3.5mA /240VAC 105~150% ratedoutputpower Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved CH1:5.75~6.75VCH2:3.8~4.4V Protectiontype: Shutdowno/pvoltage,re-powerontorecover 95 5 (TSW1) Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown -10~+60 (Refertooutputloadderatingcurve) 20~90%RHnon-condensing -20~+85 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes UL60950-1, TUVEN60950-1 Approved I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC 74% 75% I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC SAFETY & ISOLATIONRESISTANCE EMICONDUCTION&RADIATION CompliancetoEN55022(CISPR22)ClassB EMC (Note4) HARMONICCURRENT EMSIMMUNITY MTBF Complianceto EN61000-3-2,-3 Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204, EN55024,Lightindustrylevel,criteria A 139.9Khrsmin.MIL-HDBK-217F(25 199*99*50mm(L*W*H) 0.87Kg;20pcs/18.4Kg/1.28CUFT ) OTHERS NOTE DIMENSION PACKING WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 ph: 1-800-823-8082 Fax: 508-823-8181 File Name:QP-100-SPEC 2005-09-13 100WQuadOutputwithPFCFunction 1 0 0 W Q u a d O u t put with PFC Function Features: Q P --1 0 0 sseerri eess qp 100 i .. SPECIFICATION MODEL OUTPUTNUMBER DCVOLTAGE RATEDCURRENT CURRENTRANGE RATEDPOWER (max.) OUTPUT VOLTAGE ADJ.RANGE VOLTAGETOLERANCE Note.3 LINEREGULATION LOADREGULATION SETUP,RISETIME HOLDTIME (Typ.) VOLTAGERANGE FREQUENCY RANGE POWERFACTOR (Typ.) INPUT EFFICIENCY (Typ.) ACCURRENT (Typ.) INRUSHCURRENT (Typ.) LEAKAGECURRENT OVERLOAD PROTECTION OVERVOLTAGE OVERTEMPERATURE(OPTION) WORKINGTEMP. WORKINGHUMIDITY ENVIRONMENT STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTANDVOLTAGE QP-100-3D CH1 5V 8A 2~10A 104.8W CH1:4.75~5.5VCH2:3.14~3.63V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% 6.0% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 3.3V 8A 0~10A CH3 24V 1.3A 0.3~2A CH4 -12V 0.6A 0~1A QP-100D CH1 5V 8A 2~10A 100W CH1:4.75~5.5VCH2:11.4~13.2V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% 6.0% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 12V 2.4A 0~3A CH3 24V 1A 0.3~2A CH4 -12V 0.6A 0~1A QP-100F CH1 5V 8A 2~10A 103W CH1:4.75~5.5VCH2:14.3~16.5V 3.0% 1.0% 2.0% 3.0% 1.0% 2.0% 6.0% 2.0% 6.0% 5.0% 1.0% 2.0% CH2 15V 2A 0~3A CH3 24V 1A 0.3~2A CH4 -15V 0.6A 0~1A RIPPLE&NOISE(max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 180mVp-p 200mVp-p 150mVp-p 800ms,50ms/230VAC 800ms,50ms/115VACatfullload 24ms/230VAC24ms/115VACatfullload Note.5 90~264VAC127~370VDC 47~63Hz PF>0.95/230VACPF>0.98/115VACatfullload 75% 1.5A/115VAC0.75A/230VAC COLDSTART 40A/230V <3.5mA /240VAC 105~150% ratedoutputpower Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved CH1:5.75~6.75VCH2:3.8~4.4V CH1:5.75~6.75VCH2:13.8~16.2V CH1:5.75~6.75VCH2:17.25~20.25V Protectiontype: Shutdowno/pvoltage,re-powerontorecover 95 5 (TSW1) Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown -10~+60 (Refertooutputloadderatingcurve) 20~90%RHnon-condensing -20~+85 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes UL60950-1, TUVEN60950-1 Approved I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC 78% 78% I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC SAFETY & ISOLATIONRESISTANCE EMICONDUCTION&RADIATION CompliancetoEN55022(CISPR22)ClassB EMC (Note4) HARMONICCURRENT EMSIMMUNITY MTBF Complianceto EN61000-3-2,-3 Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204, EN55024,Lightindustrylevel,criteria A 139.9Khrsmin.MIL-HDBK-217F(25 199*99*50mm(L*W*H) 0.87Kg;20pcs/18.4Kg/1.28CUFT ) OTHERS NOTE DIMENSION PACKING WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 ph: 1-800-823-8082 Fax: 508-823-8181 File Name:QP-100-SPEC 2005-09-13 1 0 0 W Q u a d O u t put with PFC Function 100WQuadOutputwithPFCFunction MechanicalSpecification 199 20 55 15 168 65 qp s UQ P - -11202 s5reirei ssse r i e s S P - 00 0 e e CaseNo.916A Unit:mm LED 10 9 8 7 6 +V ADJ.2 +V ADJ.1 7.62 79 51 49.5 25 10 4-M4L=6mm 2-M4 5 6.15 4 3 2 1 5-M3L=6mm 25 117 TerminalPinNo. Assignment: PinNo. 1 2 3 Assignment AC/L AC/N FG PinNo. Assignment 4 DCOUTPUT V4 5 DCOUTPUT V3 6,7 DCOUTPUT V1 PinNo. Assignment 8,9 DCOUTPUT COM 10 DCOUTPUT V2 DeratingCurve OutputDeratingVSInputVoltage 100 100 90 80 70 60 80 70 LOAD(%) LOAD(%) 40 60 50 40 20 -10 -10 0 0 10 20 30 40 50 60 (HORIZONTAL) 90 110 115 135 12.5 155 25 50 230 264 File Name:QP-100-SPEC 2005-09-13 AMBIENTTEMPERATURE( ) INPUTVOLTAGE(VAC)60Hz WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 ph: 1-800-823-8082 Fax: 508-823-8181 38 99 |
Price & Availability of QP-100-3A |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |